SKU : FV-20WAT206V
0 Sold
no reviews
Short Description
Specifications
HP condenser motor with thermal cut-off system
Well-lubricated bearings for long service life
New specially designed impeller
Automatic louvers
Close all specifications
FV-15WAT2
FV-20WAT2
Air volume (m³/h [CFM])
210 [124]
380 [224]
Power consumption (W)
14
15
Voltage (V [Hz])
220 [50]
220 [50]
Noise level (dB/A)
43
42
Installation area (mm)
ø 186-ø188
ø 278-ø280
Weight (kg)
0.9
1.4
Note
Air volume, power consumption, and noise levels are given at a static pressure of 0 Pa.
Air volume is an average measured by our company.
Noise level is measured at 1 meter, directly from the left, right, and bottom of the product, and then the average of the three values is obtained.
Air noise level is the weighted average sound pressure level, which is the average value measured by our company.
Air volume, energy consumption, and noise levels are defined at a static pressure of 0 Pa.
Air volume is the average value measured by our company.
Sound level values are measured at 1 meter, directly from the left, right, and bottom of the product, and then the average of the three values is obtained.
Air noise level is the weighted average sound pressure level, which is the average value measured by our company.
Specifications
HP condenser motor with thermal cut-off system
Well-lubricated bearings for long service life
New specially designed impeller
Automatic louvers
Close all specifications
FV-15WAT2
FV-20WAT2
Air volume (m³/h [CFM])
210 [124]
380 [224]
Power consumption (W)
14
15
Voltage (V [Hz])
220 [50]
220 [50]
Noise level (dB/A)
43
42
Installation area (mm)
ø 186-ø188
ø 278-ø280
Weight (kg)
0.9
1.4
Note
Air volume, power consumption, and noise levels are given at a static pressure of 0 Pa.
Air volume is an average measured by our company.
Noise level is measured at 1 meter, directly from the left, right, and bottom of the product, and then the average of the three values is obtained.
Air noise level is the weighted average sound pressure level, which is the average value measured by our company.
Air volume, energy consumption, and noise levels are defined at a static pressure of 0 Pa.
Air volume is the average value measured by our company.
Sound level values are measured at 1 meter, directly from the left, right, and bottom of the product, and then the average of the three values is obtained.